[Q31-Q55] Tested Material Used To NS0-520 Test Engine Exam Questions in here [Oct-2021]

Share

Tested Material Used To NS0-520 Test Engine Exam Questions in here [Oct-2021]

Penetration testers simulate NS0-520 exam PDF

NEW QUESTION 31
You have a 2-node AFF A220 switchless cluster serving iSCSI LUNs. NetApp Volume Encryption (NVE) is enabled on all data volumes. You are asked to consolidate identical boot LUNs that are on both controllers. You need to nondisruptively consolidate LUNs with the highest storage efficiency.
In this scenario, which NetApp ONTAP technology accomplishes this task?

  • A. LIF migrate
  • B. LUN move
  • C. volume move
  • D. aggregate relocate

Answer: C

 

NEW QUESTION 32
You have a 2-node AFF A400 cluster serving iSCSI LUNs. Each A400 controller has two aggregates. The LUNs in all aggregates share data that is inline deduplicated. You are asked to enable encryption at rest to satisfy a new compliance requirement.
In this scenario, which at rest encryption solution preserves the current deduplication?

  • A. NetApp Aggregate Encryption (NAE)
  • B. Challenge Handshake Authentication Protocol (CFIAP)
  • C. NetApp Volume Encryption (NVE)
  • D. Internet Protocol Security (IPsec)

Answer: A

 

NEW QUESTION 33
Click the Exhibit button.

You need to perform an automated non-disruptive upgrade from ONTAP 9.5 to ONTAP 9.7.
Referring to the exhibit, which tool would be used?

  • A. OneCollect
  • B. AutoSupport OnDemand
  • C. Upgrade Advisor
  • D. Perfstat

Answer: C

 

NEW QUESTION 34
An administrator is planning to rehost a SAN volume from one SVM to another SVM on a FAS8300 with all hard disk drives.
After rehosting the volume, what are two policies that must be reconfigured? (Choose two.)

  • A. snapshot policy
  • B. caching policy
  • C. export policy
  • D. volume efficiency policy

Answer: A,D

 

NEW QUESTION 35
Click the Exhibit button.

Referring to the exhibit, how many LUNs should the server administrator see on the Windows 2016 host?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 36
Click the Exhibit button.

Referring to the exhibit, which WWPN would you add to a zone set to provide access to a LUN hosted in ONTAP?

  • A. 20:00:00:00:c9:43:f2:9e
  • B. 20:lb:00:a0:98:13:d5:d4
  • C. 50:0a:09:81:87:09:3d:96
  • D. 10:00:00:00:c9:43:f2:9e

Answer: D

 

NEW QUESTION 37
You are adding a new AFF A220 FIA pair to an existing FlexPod infrastructure that is using a pair of Nexus 9332PX switches. Due to rack space constraints, the AFF A220 is to be installed in an adjoining rack, and the distance from the back of the AFF A220 to the Nexus 9332PX switches is nine meters.
In this scenario, which 10Gbe cabling solution would you use to connect the AFF A220 to the Nexus 9332PX switches?

  • A. mini SAS
  • B. active Twinax
  • C. LC/LC OM4 optical
  • D. passive Twinax

Answer: C

 

NEW QUESTION 38
An administrator is testing a newly deployed SAN configuration and wants to simulate a node failure by administratively taking all FC physical ports down on a node that is serving data.
In this scenario, what should the administrator observe?

  • A. Host multipath drivers use any indirect path on the cluster to serve data.
  • B. Host multipath drivers use the HA partner's direct paths to serve data.
  • C. ALUA path states change to use the direct paths of the HA partner to serve data.
  • D. ANA path states change to use the direct paths of the HA partner to serve data.

Answer: A

 

NEW QUESTION 39
Click the Exhibit button.

You issue the cfgshow command on one of your Brocade switches and notice that there is no zoning listed under the Effective configuration. When you attempt to use the fcping command from the initiator to the target, the command fails.
Referring to the exhibit, what are two problems? (Choose two.)

  • A. There is no zoning configured, and the default zone's access is set to No Access.
  • B. The default zone access is set to allow even though zoning is defined.
  • C. There is no zone defined that has both the initiator and target in a common zone.
  • D. There is no alias for either the initiator or the target.

Answer: A,C

 

NEW QUESTION 40
You have a new 2-node AFF All SAN Array A700 cluster serving iSCSI LUNs. You are asked to test failures of the front-end protocol connections.
Which two actions satisfy the failure criteria? (Choose two.)

  • A. Perform a storage controller failover.
  • B. Pull an Ethernet cable from a Linux host.
  • C. Disable Snapshot policies.
  • D. Pull an Ethernet cable from a storage port with a cluster LIF.

Answer: A,B

 

NEW QUESTION 41
You are an administrator of a multi-tenanted cluster which hosts multiple SVMs. One of your tenants requires management access to their SVM for SnapCenter to perform a backup. You are asked by the backup team to create a dedicated user account and management LIF for this purpose.
In this scenario, which LIF role would be associated with management access?

  • A. Cluster
  • B. Intercluster
  • C. Data
  • D. Node Management

Answer: C

 

NEW QUESTION 42
Your company has begun to require additional restrictions on systems in the cloud. To comply with these new restrictions, you must have all incoming connections authorized to your Cloud Volumes ONTAP instance in Amazon Web Services (AWS).
Which two features enable you to satisfy your company's requirements for Red Hat Enterprise Linux 7 iSCSI hosts? (Choose two.)

  • A. routing failover groups
  • B. Challenge-Handshake Authentication Protocol (CHAP)
  • C. iSCSI endpoint isolation
  • D. single initiator zoning

Answer: B,C

 

NEW QUESTION 43
An administrator added the FCP protocol to an SVM and created a LUN for a Windows Server 2019 server. After a rescan, the LUN is not visible on the host.
Which two statements describe how to solve this problem? (Choose two.)

  • A. Create an igroup, add the WWPN of the host initiator, and then map the igroup to the LUN.
  • B. Perform takeover and giveback of both controllers.
  • C. Disable and enable the FC port with the attached host, causing a FLOGI.
  • D. Create a zone with a single initiator and the target LIF's WWPN.

Answer: A,D

 

NEW QUESTION 44
Click the Exhibit button.

An administrator has added two nodes to an existing cluster. The administrator created the svfc2 SVM to use FC to present LUNs to hosts. The hosts are unable to see the LUNs that have been presented to them.
Referring to the exhibit, what is the problem?

  • A. The FC ports show the status of admin down.
  • B. The FC service on the SVM has been stopped.
  • C. The FC protocol needs to be added to the allowed protocols list.
  • D. The UTA mode change Is pending a reboot.

Answer: D

 

NEW QUESTION 45
Click the Exhibit button.

A customer is troubleshooting an AFF A700 2-node cluster that is running out of space. They need to add two additional shelves, one shelf to stack-1, and a shelf to stack-2.
Referring to the exhibit, how many cables are required?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 46
You just finished installing and configuring a new NetApp AFF All SAN Array environment.
In this scenario, which two tools would you use to verify that the environment satisfies best practices? (Choose two.)

  • A. Active IQ Unified Manager
  • B. ONTAP System Manager
  • C. Active IQ OneCollect
  • D. Active IQ Config Advisor

Answer: C,D

 

NEW QUESTION 47
Click the Exhibit button.

Referring to the exhibit, which two Fibre Channel names should you zone on the FC switch to provide connectivity to the LUN? (Choose two.)

  • A. 20:00:00:50:56:9c:16:cc
  • B. 20:01:00:50:56:9c:16:cc
  • C. 50:0a:09:82:9c:7a:4e:00
  • D. 50:0a:09:82:9c:16:cc:00

Answer: A,B

 

NEW QUESTION 48
Click the Exhibit button.

The storage system reports that one or more of the FC LIFs have the administratively up and operationally down status. Initiators are unable to connect to the affected LIFs or access LUNs that are presented by those LIFs.
Referring to the exhibit, which command fields provide port login details with the switch?

  • A. media-type
  • B. status-extended
  • C. conn-established
  • D. fabric-established

Answer: D

 

NEW QUESTION 49
Click the Exhibit button.

Referring to the exhibit, which step must be performed to make LUN lun0 available to hosts in igroup linux1?

  • A. node-03 and node-04 must be added to the list of reporting nodes.
  • B. node-01 and node-02 must be removed from the list of reporting nodes.
  • C. lun0 must be mapped to linux1.
  • D. lun0 must be brought online.

Answer: D

 

NEW QUESTION 50
An administrator enabled the iSCSI protocol on an SVM and created a LUN for a VMware ESXi server.
After the administrator performs a rescan, the LUN is not visible on the host.
Which statement describes how to solve this problem?

  • A. Create an igroup, add the iSCSI IQN, then map the LUN to the igroup.
  • B. Perform a takeover/giveback of the controller that is hosting the LUN.
  • C. Create an igroup, add the WWPN of the host initiator, then map the LUN to the igroup.
  • D. Enable ALUA support on the VMware host.

Answer: A

 

NEW QUESTION 51
You have an SVM serving LUNs to your VMware environment. You have configured the SAN LIFs, zoning, and multipath by using industry best practices. You need to temporarily migrate a SAN LIF to another host, preserving the SAN LIF's WWPN. You do not want to lose access to the LUNs during LIF migration.
In this scenario, what are three required steps that are needed to accomplish this task? (Choose three.)

  • A. Nondisruptively migrate the LIF to the destination host.
  • B. Set the new home node and home port in the LIF.
  • C. Bring the LIF online.
  • D. Take the LIF offline.
  • E. Update the zone using the WWPN of the destination host's physical port.

Answer: B,C,D

 

NEW QUESTION 52
An administrator wants to connect a DS460C disk shelf to a FAS9000.
Which two statements are correct in this scenario? (Choose two.)

  • A. A C13/C14 power cable and compatible rack power distribution unit are required.
  • B. A Telco rack is required
  • C. A deep rack is required
  • D. A C19/C20 power cable and compatible rack power distribution unit are required.

Answer: C,D

 

NEW QUESTION 53
You have a 2-node AFF A400 serving FC LUNs. You are asked to make an instant-writable copy of a LUN in a deduplicated volume. The writable copy must not take additional space.
In this scenario, which two ONTAP features would be used? (Choose two.)

  • A. clone split
  • B. LUN move
  • C. file clone
  • D. volume clone

Answer: C,D

 

NEW QUESTION 54
An administrator is asked to provide enhanced security measures to an iSCSI LUN using the Challenge Handshake Authentication Protocol (CHAP) with the iscsi security create command.
In this scenario, for which two objects should the administrator configure CHAP? (Choose two.)

  • A. for the iSCSI LUN
  • B. for the target IQN or EUI
  • C. for the initiator IQN or EUI
  • D. for the volume containing the iSCSI LUN

Answer: A,C

 

NEW QUESTION 55
......


NetApp NS0-520 Exam Certification Details:

Number of Questions60
Exam NameImplementation Engineer SAN Specialist, ONTAP
Exam CodeNS0-520 NCIE SAN Specialist, ONTAP
Recommended TrainingONTAP SAN Fundamentals (WBT)
SAN Administration
SAN Implementation (ILT)
Sample QuestionsNetApp NS0-520 Sample Questions
Passing Score62%
Exam RegistrationPEARSON VUE
Duration90 minutes
Exam Price$150 USD

 

Authentic Best resources for NS0-520 Online Practice Exam: https://www.newpassleader.com/NetworkAppliance/NS0-520-exam-preparation-materials.html