[Dec-2021] Get 100% Real 010-151 Exam Questions, Accurate & Verified NewPassLeader Dumps in the Real Exam! [Q32-Q57]

Share

[Dec-2021] Get 100% Real 010-151 Exam Questions, Accurate & Verified NewPassLeader Dumps in the Real Exam!

Pass Your CCT Data Center Exams Fast. All Top 010-151 Exam Questions Are Covered.

NEW QUESTION 32
Which processor option is supported in the Cisco UCS C420 M3 Server?

  • A. up to two Intel Xeon E5-4600 series multicore processors
  • B. up to two Intel Xeon E7-4800 series multicore processors
  • C. up to four Intel Xeon E5-4600 series multicore processors
  • D. two or four Intel Xeon E7-8800 series multicore processors

Answer: C

 

NEW QUESTION 33
Which two statements about PCIe are true? (Choose two.)

  • A. The PCIe 1.0 standard doubles the transfer rate compared to PCIe 2.0.
  • B. You can install a PCI Express x8 adapter into an x4 slot.
  • C. The PCIe link is built around dedicated unidirectional couples of serial, point-to-point connections known as lanes.
  • D. The PCIe standard is a bus-based system in which all the devices share the same bidirectional, 32-bit or
    64-bit, parallel signal path.
  • E. A link that is composed of four lanes is called an x4 link.

Answer: C,E

 

NEW QUESTION 34
Which type of optics module is supported by a 6-port 40 GE Cisco Nexus 7000 M2 Series I/O module?

  • A. SFP/SFP+
  • B. CFP
  • C. QSFP+
  • D. CPAK

Answer: C

 

NEW QUESTION 35
What is the wire transmission speed for 100GBASE-ER4 Ethernet?

  • A. 10 Gb/s
  • B. 1 Gb/s
  • C. 100 Gb/s
  • D. 100 Mb/s

Answer: C

Explanation:
Explanation/Reference:
updated.

 

NEW QUESTION 36

Refer to the exhibit. Which item does F represent?

  • A. HDD 1
  • B. CPU 2
  • C. CMOS Battery
  • D. SuperCap Module
  • E. TFP Module

Answer: B

 

NEW QUESTION 37
Which three tools are necessary to console into a Cisco UCS C-Series Rack-Mount Server? (Choose three.)

  • A. Cisco DB-9-to-RJ-45 console cable
  • B. keyboard
  • C. KVM dongle
  • D. USB serial adapter
  • E. laptop
  • F. monitor

Answer: B,C,F

 

NEW QUESTION 38
Which supervisor module is supported by a Cisco Nexus 7700 Series Switch?

  • A. second-generation supervisor enhanced module (Sup2E)
  • B. first-generation supervisor module
  • C. third-generation supervisor enhanced module (Sup3E)
  • D. second-generation supervisor module (Sup2)

Answer: A

Explanation:
Explanation/Reference:

 

NEW QUESTION 39
Which two firmware components does the Host Upgrade Utility upgrade? (Choose two.)

  • A. System BIOS
  • B. Fabric Interconnect firmware
  • C. CIMC
  • D. Cisco UCS Infrastructure software
  • E. Cisco UCS Manager

Answer: A,C

Explanation:
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/sw/lomug/2-0-x/3_0/b_huu_3_0_1/ b_huu_2_0_13_chapter_011.html

 

NEW QUESTION 40
Refer to the exhibit.

Which statement correctly identifies the front panel LEDs on the Cisco UCS C220 Server?

  • A. A is network link activity LED; B is system status LED; C is power button and power status LED; D is identification button and LED.
  • B. A is network link activity LED; B is system status LED; C is identification button and LED; D is power button and power status LED.
  • C. A is system status LED; B is network link activity LED; C is power button and power status LED; D is identification button and LED.
  • D. A is power button and power status LED; B is identification button and LED; C is system status LED; D is network link activity LED.

Answer: D

 

NEW QUESTION 41
Which two statements are true about the Cisco UCS C4200 Rack server and UCS C125 M5 compute node?
(Choose two.)

  • A. 2666-MHz DDR4 memory and 24 DIMM slots for up to 3 TB of total memory
  • B. 8 NVIDIA SXM2 V100 32G modules with NVLink interconnect
  • C. Over 45 TB of storage, with up to six small-form-factor 2.5-inch direct-attached drives per node
  • D. AMD EPYC 7000 series processors, with up to 32 cores per socket
  • E. Optional dual USB ports for increased storage or boot drive capacity

Answer: C,E

 

NEW QUESTION 42
Where do you find the model number of a Cisco MDS 9200 Series chassis?

  • A. on the top front of the chassis next to the serial number
  • B. on the top front of the chassis next to the Cisco logo
  • C. on the bottom front of the chassis next to the Cisco logo
  • D. on the bottom front of the chassis next to the serial number

Answer: B

 

NEW QUESTION 43
Which supervisor module is supported by a Cisco Nexus 7700 Series Switch?

  • A. second-generation supervisor enhanced module (Sup2E)
  • B. first-generation supervisor module
  • C. third-generation supervisor enhanced module (Sup3E)
  • D. second-generation supervisor module (Sup2)

Answer: A

 

NEW QUESTION 44
What is the wire transmission speed for 100GBASE-ER4 Ethernet?

  • A. 10 Gb/s
  • B. 1 Gb/s
  • C. 100 Gb/s
  • D. 100 Mb/s

Answer: C

 

NEW QUESTION 45
Which three statements about powering down a Cisco UCS C-Series Rack-Mount Server to perform maintenance or replacement are true? (Choose three.)

  • A. Graceful shutdown: Press and release the power button. The operating system performs a graceful shutdown, and the server goes to standby mode, which is indicated by an amber power status LED.
  • B. The Cisco UCS C-Series Rack-Mount Server has only one power mode.
  • C. Power status LED. Green indicates that the server is in main power mode and can be safely powered off.
  • D. Disconnect the power cords from the power supplies in your server to completely power off the server.
  • E. Only an emergency shutdown can be performed using the power button on the server front panel.
  • F. Standby power mode: Power is supplied only to the service processor and the cooling fans, and it is safe to power off the server from this mode.

Answer: A,D,F

 

NEW QUESTION 46
The Ethernet specification details several different fiber optic media types. What is the wire transmission speed for 100BASE-FX Ethernet?

  • A. 10 Mb/s
  • B. 1000 Mb/s
  • C. 10000 Mb/s
  • D. 100 Mb/s

Answer: D

 

NEW QUESTION 47
Refer to the exhibit.

Which item does A represent?

  • A. mLOM for Cisco UCS B420 M3 Blade Servers
  • B. SuperCap module for Cisco UCS B420 M3 Blade Servers
  • C. Virtual Interface Card for Cisco UCS B420 M3 Blade Servers
  • D. Virtual Emulex Adapter Card for Cisco UCS B420 M3 Blade Servers
  • E. Emulex Adapter Card for Cisco UCS B420 M3 Blade Servers

Answer: A

 

NEW QUESTION 48
Which two cable types can support 10Gbps speed? (Choose two.)

  • A. CAT5a
  • B. CAT6a
  • C. CAT5
  • D. CAT7
  • E. CAT5e

Answer: B,D

 

NEW QUESTION 49
Refer to the exhibit.

Which three options are features of the Cisco UCS 6248UP Fabric Interconnect front panel? (Choose three.)

  • A. Fan module
  • B. USB port
  • C. Console port
  • D. 10 Gb/s port
  • E. FCoE port

Answer: A,B,C

 

NEW QUESTION 50
Which two statements are true about system controllers of Cisco Nexus 9500 Series? (Choose two.)

  • A. They are used to offload the internal non-data-path switching and management functions from the supervisor engines.
  • B. The Cisco Nexus 9500 Series switch software, Enhanced NX-OS, runs on the system controllers.
  • C. They provide centralized arbitration to the system fabric for all line cards.
  • D. The Cisco Nexus 9500 Series supports redundant system controllers.
  • E. They control the Layer 2 and Layer 3 services.

Answer: A,D

 

NEW QUESTION 51
Refer to the exhibit.

Where is the best place to see bootflash free space?

  • A. A - Available Memory
  • B. B - Total Memory
  • C. D - High Availability Details
  • D. C - Local Storage Information

Answer: D

 

NEW QUESTION 52
Which two statements about the Cisco Nexus 5596UP switch are true? (Choose two.)

  • A. It supports unified ports.
  • B. It has one expansion slot.
  • C. It is offered in a one-rack-unit form factor.
  • D. Its power supplies and fan trays are hot-swappable.
  • E. It supports up to 96 10G BASE-T ports.

Answer: A,D

 

NEW QUESTION 53
Refer to the exhibit.

Where is the best place to see the power supply status of the blade server enclosure?

  • A. E - Fabric Interconnects A - PSUs
  • B. C - Chassis1 - Servers
  • C. B - Chassis 1 - PSUs
  • D. A - Chassis 1
  • E. D - Rack-Mounts - Servers

Answer: C

 

NEW QUESTION 54
Refer to the exhibit.

What is the name of this rack-mount server?

  • A. Cisco UCS C420 Rack-Mount Server
  • B. Cisco UCS C220 Rack-Mount Server
  • C. Cisco UCS C460 Rack-Mount Server
  • D. Cisco UCS C240 Rack-Mount Server

Answer: A

Explanation:
Explanation

 

NEW QUESTION 55
Refer to the exhibit.

Which three options are features of the Cisco UCS 6248UP Fabric Interconnect front panel? (Choose three.)

  • A. Fan module
  • B. USB port
  • C. Console port
  • D. 10 Gb/s port
  • E. FCoE port

Answer: A,B,C

Explanation:
Explanation/Reference:

 

NEW QUESTION 56
What is the maximum number of supervisor modules that the Cisco MDS 9710 Switch supports?

  • A. 0
  • B. 1
  • C. 2
  • D. 3
  • E. 4

Answer: C

 

NEW QUESTION 57
......


Cisco Certified Technician Data Center (010-151) Exam Intro

The Cisco Certified Technician Data Center (CCT data center) should be able to perform repair (hardware failure repair) services on Cisco data center products, including backup and recovery of software and configuration, verify safety and environmental requirements. It also deals with the ability to recognize the connection type and cable requirements and perform basic physical layer troubleshooting.


Cisco 010-151 Exam Topics:

SectionWeightObjectives

Service-Related Information

33%

1. Use the hardware tools needed for repair
2. Make a physical connection from laptop to Cisco console port
3. Perform installation process steps and expected outcomes
4. Perform initial setup tasks
5. Service restoration verification
6. Perform remedial procedures on Cisco devices
7. Upgrade the BIOS on a Cisco UCS Server Blade with the GUI
8. Perform Cisco UCS Fabric Interconnect (FI) upgrade/downgrade procedure
9. Firmware Automatic Synchronization
10. Upgrade Cisco Integrated Management Controller firmware on a Cisco UCS Server C-Series
11. Troubleshoot Cisco UCS servers

Data Center Basics17%

1. Describe a data center
2. Describe cloud computing
3. Describe virtualization (server, network and storage)
4. Describe PCIe SSDs and NVMe
5. Describe raid storage
6. Differentiate between these Layer 2 technologies (Ethernet, Fast Ethernet, Gigabit Ethernet)
7. Describe SAN technology (SAN network type)
8. Describe SAN cabling (FCoE, PCIe)
9. Describe UTP and connectors
10. Describe fiber and connectors
11. Describe twinaxial and connectors
12. Describe SFP and QSFP transceivers

Cisco Equipment and Related Hardware

25%

1. Describe the Cisco Unified Computing System (UCS) components
2. Describe the Cisco UCS B-series Blade servers components and chassis layout
3. Describe the Cisco UCS C-series rack mount servers components and chassis layout
4. Describe Cisco UCS fabric interconnects and fabric extenders
5. Identify the Cisco UCS LED and chassis layout
6. Describe the Cisco UCS network adapters and expansion modules
7. Describe the Cisco UCS S-series Storage servers components and chassis layout
8. Describe the Cisco UCS E-series servers components and chassis layout
9. Describe the Cisco Nexus switches family components
10. Describe Cisco ACI and NX-OS mode
11. Describe the Cisco MDS 9700 product family components
12. Identifying the MDS 9700 Family Storage networking modules

Cisco UCS and Cisco NX-OS software operation

25%

1. Describe the Cisco Integrated Management Controller (CIMC)
2. Describe features and functionality of Cisco UCS Manager
3. Describe the different command modes for Cisco NX-OS software
4. Determine the current mode of the device
5. Verify the device configuration
6. Know how to use and interpret the basic Cisco NX-OS commands
7. Identify a configuration file from a Cisco device
8. Using the device file systems, directories, and files
9. Perform password recovery on a Cisco NX-OS switch device



You can read the Registration procedure of the Cisco Certified Technician Data Center (010-151) Exam

In order to apply for the Cisco Certified Technician Data Center (010-151), You have to follow these steps

  • Step 1: Visit to Pearson VUE Exam Registration
  • Step 2: Signup/Login to Pearson VUE account
  • Step 3: Search for Cisco 010-151 Certifications Exam
  • Step 4: Select Date, time and confirm with a payment method

Penetration testers simulate 010-151 exam: https://www.newpassleader.com/Cisco/010-151-exam-preparation-materials.html

Free Test Engine For Supporting Cisco Datacenter Networking Devices (DCTECH) Certification Exams: https://drive.google.com/open?id=1xXLTJhpBBdhgyRmUeYA_2VEcgWYQwhQC